<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Switches / Disconnectors &#8211; Laboratorio Electrotécnico</title>
	<atom:link href="https://lescop.com/en/productos/switches-disconnectors/feed/" rel="self" type="application/rss+xml" />
	<link>https://lescop.com/en/</link>
	<description>Transformadores a medida, aparellaje eléctrico</description>
	<lastBuildDate>Fri, 17 Dec 2021 09:57:29 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>
	<item>
		<title>MOL-3. 3 Pole Breaker.</title>
		<link>https://lescop.com/en/catalogo/railway-sector-adif/mol-3-3-pole-breaker/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Wed, 07 Aug 2019 09:21:02 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/uncategorized/mol-3-3-pole-breaker/</guid>

					<description><![CDATA[<p style="font-weight: 400;"><span class="tlid-translation translation" lang="en"><span class="" title="">The <strong>Mol-3</strong> is a <strong>tripolar disconnector switch</strong>, double breaking system, encapsulated in resin, for general use.</span></span></p>

<ul>
 	<li style="list-style-type: none;">
<ul>
 	<li style="list-style-type: none;">
<ul>
 	<li>Rated voltage: 3.6 kV</li>
 	<li>Rated current: 100 A</li>
 	<li>Rated breaking capability: 100 A</li>
 	<li>Rated making capability in d.c: 2.5 kA.</li>
</ul>
</li>
</ul>
</li>
</ul>
Types:
- <strong>MOL-3,</strong> for looping lines.
- <strong>MOL-3/C</strong>, for branch lines and protection.

<span class="tlid-translation translation" lang="en"><span class="" title="">Manufactured according to <strong>UNE-EN 62271-1</strong> and <strong>UNE-EN 62271-103</strong>.</span></span>

&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/Mol-3F_tripolar_Catalogo_Ingles_2019.pdf">3<span class="tlid-translation translation" lang="en"><span class="" title="">-pole Mol-3 Catalog</span></span></a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Manual_Instrucciones_Mol-3_Web.pdf">User manual Mol-3.pdf</a>]]></description>
										<content:encoded><![CDATA[<p style="font-weight: 400;"><span class="tlid-translation translation" lang="en"><span class="" title="">The <strong>Mol-3</strong> is a <strong>tripolar disconnector switch</strong>, double breaking system, encapsulated in resin, for general use.</span></span></p>

<ul>
 	<li style="list-style-type: none;">
<ul>
 	<li style="list-style-type: none;">
<ul>
 	<li>Rated voltage: 3.6 kV</li>
 	<li>Rated current: 100 A</li>
 	<li>Rated breaking capability: 100 A</li>
 	<li>Rated making capability in d.c: 2.5 kA.</li>
</ul>
</li>
</ul>
</li>
</ul>
Types:
- <strong>MOL-3,</strong> for looping lines.
- <strong>MOL-3/C</strong>, for branch lines and protection.

<span class="tlid-translation translation" lang="en"><span class="" title="">Manufactured according to <strong>UNE-EN 62271-1</strong> and <strong>UNE-EN 62271-103</strong>.</span></span>

&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/Mol-3F_tripolar_Catalogo_Ingles_2019.pdf">3<span class="tlid-translation translation" lang="en"><span class="" title="">-pole Mol-3 Catalog</span></span></a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Manual_Instrucciones_Mol-3_Web.pdf">User manual Mol-3.pdf</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2386</post-id>	</item>
		<item>
		<title>MOL-2. Bipolar Switch.</title>
		<link>https://lescop.com/en/catalogo/railway-sector-adif/mol-2-bipolar-switch/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Wed, 07 Aug 2019 08:47:12 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/uncategorized/mol-2-bipolar-switch/</guid>

					<description><![CDATA[<p style="font-weight: 400;"><span class="tlid-translation translation" lang="en"><span class="" title="">The <strong>MOL-2</strong> is a <strong>bipolar switch-disconnector</strong>, double breaking system, encapsulated in resin, for general use.</span></span></p>

<ul>
 	<li style="list-style-type: none;">
<ul>
 	<li style="list-style-type: none;">
<ul>
 	<li>Rated voltage: 3.6 k</li>
 	<li>Rated current: 200 A</li>
 	<li>Rated breaking capability: 200 A</li>
 	<li>Rated making capability in d.c: 7.5 kA.</li>
</ul>
</li>
</ul>
</li>
</ul>
<p style="font-weight: 400;">Types:</p>
- <strong>MOL-2</strong> for looping lines.
- <strong>MOL-2/C</strong> for branch lines and protection.

<span class="tlid-translation translation" lang="en"><span class="" title="">Manufactured according to</span></span><strong><span class="tlid-translation translation" lang="en"><span class="" title=""> UNE-EN 62271-1 </span></span></strong><span class="tlid-translation translation" lang="en"><span class="" title="">and</span></span><strong><span class="tlid-translation translation" lang="en"><span class="" title=""> UNE-EN 62271-103.</span></span></strong>

&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/Mol-2_bipolar_Catalogo_Castellano_2019.pdf">Mol-2 bipolar Catalog</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Manual_Instrucciones_Mol-2_Web.pdf">User Manual Mol-2</a>]]></description>
										<content:encoded><![CDATA[<p style="font-weight: 400;"><span class="tlid-translation translation" lang="en"><span class="" title="">The <strong>MOL-2</strong> is a <strong>bipolar switch-disconnector</strong>, double breaking system, encapsulated in resin, for general use.</span></span></p>

<ul>
 	<li style="list-style-type: none;">
<ul>
 	<li style="list-style-type: none;">
<ul>
 	<li>Rated voltage: 3.6 k</li>
 	<li>Rated current: 200 A</li>
 	<li>Rated breaking capability: 200 A</li>
 	<li>Rated making capability in d.c: 7.5 kA.</li>
</ul>
</li>
</ul>
</li>
</ul>
<p style="font-weight: 400;">Types:</p>
- <strong>MOL-2</strong> for looping lines.
- <strong>MOL-2/C</strong> for branch lines and protection.

<span class="tlid-translation translation" lang="en"><span class="" title="">Manufactured according to</span></span><strong><span class="tlid-translation translation" lang="en"><span class="" title=""> UNE-EN 62271-1 </span></span></strong><span class="tlid-translation translation" lang="en"><span class="" title="">and</span></span><strong><span class="tlid-translation translation" lang="en"><span class="" title=""> UNE-EN 62271-103.</span></span></strong>

&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/Mol-2_bipolar_Catalogo_Castellano_2019.pdf">Mol-2 bipolar Catalog</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Manual_Instrucciones_Mol-2_Web.pdf">User Manual Mol-2</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2375</post-id>	</item>
		<item>
		<title>FUC/C. Fuse-Breaker.</title>
		<link>https://lescop.com/en/catalogo/switches-disconnectors/fuc-c-fuse-breaker/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Wed, 07 Aug 2019 08:38:21 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/uncategorized/fuc-c-fuse-breaker/</guid>

					<description><![CDATA[<p style="font-weight: 400; text-align: justify;">The <strong>FUC/C</strong> is a <strong>fuse-breaker combined</strong> device <strong>for general use</strong>, equipped with an automatic tripping device.</p>
<p style="font-weight: 400; text-align: justify;">For lines from <strong>12 to 36 kV</strong>, and current of <strong>400A </strong>and<strong> 630A</strong>.</p>
<p style="font-weight: 400; text-align: justify;">Equipped with automatic tripping device. Fuses fitted with striker generate automatic opening of the three poles when the striker of any of them acts.</p>
<p style="font-weight: 400; text-align: justify;">The automatic opening of the FUC/C can be originated by:
- The fuse bolts
- Direct relays type PTE-4
- Disconnection relay to emission of current.</p>
<p style="font-weight: 400; text-align: justify;"><span class="tlid-translation translation" lang="en"><span class="" title="">Manufactured according to <strong>IEC 62271-1</strong> and <strong>IEC 62271-103.</strong></span></span></p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/FUCC_FUCCm_Catalogo_Ingles_2019.pdf">FUCC / FUCCm Catalog</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Catalogo_Aparellaje-Completo_2019.pdf">Switchgear Catalog</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Manual_Instrucciones_FUC_WEB.pdf">User Manual FUC</a>]]></description>
										<content:encoded><![CDATA[<p style="font-weight: 400; text-align: justify;">The <strong>FUC/C</strong> is a <strong>fuse-breaker combined</strong> device <strong>for general use</strong>, equipped with an automatic tripping device.</p>
<p style="font-weight: 400; text-align: justify;">For lines from <strong>12 to 36 kV</strong>, and current of <strong>400A </strong>and<strong> 630A</strong>.</p>
<p style="font-weight: 400; text-align: justify;">Equipped with automatic tripping device. Fuses fitted with striker generate automatic opening of the three poles when the striker of any of them acts.</p>
<p style="font-weight: 400; text-align: justify;">The automatic opening of the FUC/C can be originated by:
- The fuse bolts
- Direct relays type PTE-4
- Disconnection relay to emission of current.</p>
<p style="font-weight: 400; text-align: justify;"><span class="tlid-translation translation" lang="en"><span class="" title="">Manufactured according to <strong>IEC 62271-1</strong> and <strong>IEC 62271-103.</strong></span></span></p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/FUCC_FUCCm_Catalogo_Ingles_2019.pdf">FUCC / FUCCm Catalog</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Catalogo_Aparellaje-Completo_2019.pdf">Switchgear Catalog</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Manual_Instrucciones_FUC_WEB.pdf">User Manual FUC</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2373</post-id>	</item>
		<item>
		<title>FUC. On Load Breaker.</title>
		<link>https://lescop.com/en/catalogo/switches-disconnectors/fuc-on-load-breaker/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Wed, 07 Aug 2019 08:25:48 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/uncategorized/fuc-on-load-breaker/</guid>

					<description><![CDATA[<p style="font-weight: 400; text-align: justify;"><span class="tlid-translation translation" lang="en"><span class="" title="">The <strong>FUC</strong> is a <strong>switch-disconnector in load</strong>, of <strong>three-pole interior service</strong>, for general use.</span></span></p>
<p style="font-weight: 400; text-align: justify;">Designed for lines <strong>12 to 36 kV</strong>, and current of <strong>400A</strong> and <strong>630A</strong>.</p>
<p style="font-weight: 400; text-align: justify;">Supplied with epoxy resin insulators. Equipped with an auto-pneumatic blowing system, it is equally effective in breaking active load currents, transformer load currents and off-circuit cables.</p>
<p style="font-weight: 400; text-align: justify;">Manufactured according to <span class="tlid-translation translation" lang="en"><span class="" title=""><strong>IEC 62271-1</strong> and </span></span><strong>IEC 62271-103</strong> standard.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/FUC_FUCD_Catalogo_Ingles_2019.pdf">FUC / FUCD Catalog</a>

<a href="https://lescop.com/wp-content/uploads/2019/08/Catalogo-Aparellaje-1.pdf" target="_blank" rel="noopener noreferrer">Switchgear Catalog</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Manual_Instrucciones_FUC_WEB.pdf">User Manual FUC</a>]]></description>
										<content:encoded><![CDATA[<p style="font-weight: 400; text-align: justify;"><span class="tlid-translation translation" lang="en"><span class="" title="">The <strong>FUC</strong> is a <strong>switch-disconnector in load</strong>, of <strong>three-pole interior service</strong>, for general use.</span></span></p>
<p style="font-weight: 400; text-align: justify;">Designed for lines <strong>12 to 36 kV</strong>, and current of <strong>400A</strong> and <strong>630A</strong>.</p>
<p style="font-weight: 400; text-align: justify;">Supplied with epoxy resin insulators. Equipped with an auto-pneumatic blowing system, it is equally effective in breaking active load currents, transformer load currents and off-circuit cables.</p>
<p style="font-weight: 400; text-align: justify;">Manufactured according to <span class="tlid-translation translation" lang="en"><span class="" title=""><strong>IEC 62271-1</strong> and </span></span><strong>IEC 62271-103</strong> standard.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/FUC_FUCD_Catalogo_Ingles_2019.pdf">FUC / FUCD Catalog</a>

<a href="https://lescop.com/wp-content/uploads/2019/08/Catalogo-Aparellaje-1.pdf" target="_blank" rel="noopener noreferrer">Switchgear Catalog</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Manual_Instrucciones_FUC_WEB.pdf">User Manual FUC</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2369</post-id>	</item>
		<item>
		<title>SILE. No load switch.</title>
		<link>https://lescop.com/en/catalogo/switches-disconnectors/sile-no-load-switch/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Thu, 01 Aug 2019 15:55:01 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/uncategorized/seccionador-sile-en-vacio/</guid>

					<description><![CDATA[<p style="font-weight: 400; text-align: justify;"><span style="font-style: inherit; font-weight: inherit;">The <strong>Sile</strong> is a <strong>tripolar no-load switch</strong> for <strong>indoor service</strong>, for general use.</span></p>
<p style="font-weight: 400; text-align: justify;">It is designed for lines from <strong>12 to 36 kV</strong>, and current of <strong>400 -</strong> <strong>630A </strong>and<strong> 1000 - 1200A</strong>.</p>
<p style="font-weight: 400; text-align: justify;"><span style="font-style: inherit; font-weight: inherit;">Models:</span></p>
<p style="text-align: left;">- <strong>SILE-12</strong>: rated voltage of 12 kV
- <strong>SILE-24</strong>: rated voltage of 24 kV
- <strong>SILE-36 &#38; SILE-36.1</strong>: rated voltage of 36 kV</p>
<p style="font-weight: 400; text-align: justify;">Manufactured according to <strong>IEC 62271-1 </strong>and<strong> IEC 62271-102 </strong>standard<strong>.</strong></p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/SILE_Catalogo_Ingles_2019.pdf" target="_blank" rel="noopener noreferrer">SILE Catalog</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Catalogo_Aparellaje-Tipos_de_accionamientos_maniobras_2019.pdf">Types of operation</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Catalogo_Aparellaje-Ejemplo_de_maniobras_2019.pdf">Example types of drive</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Manual_Instrucciones_SILE_WEB.pdf">Manual Instrucciones SILE</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Catalogo_Aparellaje-Completo_2019.pdf" target="_blank" rel="noopener noreferrer">Switchgear Catalog</a>]]></description>
										<content:encoded><![CDATA[<p style="font-weight: 400; text-align: justify;"><span style="font-style: inherit; font-weight: inherit;">The <strong>Sile</strong> is a <strong>tripolar no-load switch</strong> for <strong>indoor service</strong>, for general use.</span></p>
<p style="font-weight: 400; text-align: justify;">It is designed for lines from <strong>12 to 36 kV</strong>, and current of <strong>400 -</strong> <strong>630A </strong>and<strong> 1000 - 1200A</strong>.</p>
<p style="font-weight: 400; text-align: justify;"><span style="font-style: inherit; font-weight: inherit;">Models:</span></p>
<p style="text-align: left;">- <strong>SILE-12</strong>: rated voltage of 12 kV
- <strong>SILE-24</strong>: rated voltage of 24 kV
- <strong>SILE-36 &#38; SILE-36.1</strong>: rated voltage of 36 kV</p>
<p style="font-weight: 400; text-align: justify;">Manufactured according to <strong>IEC 62271-1 </strong>and<strong> IEC 62271-102 </strong>standard<strong>.</strong></p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/SILE_Catalogo_Ingles_2019.pdf" target="_blank" rel="noopener noreferrer">SILE Catalog</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Catalogo_Aparellaje-Tipos_de_accionamientos_maniobras_2019.pdf">Types of operation</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Catalogo_Aparellaje-Ejemplo_de_maniobras_2019.pdf">Example types of drive</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Manual_Instrucciones_SILE_WEB.pdf">Manual Instrucciones SILE</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Catalogo_Aparellaje-Completo_2019.pdf" target="_blank" rel="noopener noreferrer">Switchgear Catalog</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2323</post-id>	</item>
		<item>
		<title>SILE-U. No load Unipole Switch.</title>
		<link>https://lescop.com/en/catalogo/switches-disconnectors/sile-u-switch-vacuum-pole/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Wed, 07 Aug 2019 07:27:47 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/uncategorized/sile-u-switch-vacuum-pole/</guid>

					<description><![CDATA[<p style="text-align: justify;">The <strong>Sile-U</strong> is an <strong>unipolar no-load switch</strong> for <strong>indoor service</strong>, for general use.</p>
<p style="text-align: justify;">It is designed for lines from <strong>12 to 36 kV</strong>, and current of <strong>400A</strong> and <strong>630A</strong>.</p>
<p style="text-align: justify;">It is mounted on a frame of rolled steel, protected against corrosion by epoxy paint. The splitting blade consist of two tracks in parallel and a central contact, actuated by a connecting rod.</p>
<p style="text-align: justify;">Manufactured according to <strong>IEC 62271-1 </strong>and <strong>IEC 62271-102</strong> standard.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/SILE-U_Catalogo_Castellano_2019.pdf">SILE-U Catalog</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Catalogo_Aparellaje-Tipos_de_accionamientos_maniobras_2019.pdf">Types of Operation</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Catalogo_Aparellaje-Ejemplo_de_maniobras_2019.pdf">Example types of drive</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Catalogo_Aparellaje-Completo_2019.pdf">Switchgear Catalog</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Manual_Instrucciones_SILE-U_WEB.pdf">User Manual SILE-U</a>]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;">The <strong>Sile-U</strong> is an <strong>unipolar no-load switch</strong> for <strong>indoor service</strong>, for general use.</p>
<p style="text-align: justify;">It is designed for lines from <strong>12 to 36 kV</strong>, and current of <strong>400A</strong> and <strong>630A</strong>.</p>
<p style="text-align: justify;">It is mounted on a frame of rolled steel, protected against corrosion by epoxy paint. The splitting blade consist of two tracks in parallel and a central contact, actuated by a connecting rod.</p>
<p style="text-align: justify;">Manufactured according to <strong>IEC 62271-1 </strong>and <strong>IEC 62271-102</strong> standard.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/SILE-U_Catalogo_Castellano_2019.pdf">SILE-U Catalog</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Catalogo_Aparellaje-Tipos_de_accionamientos_maniobras_2019.pdf">Types of Operation</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Catalogo_Aparellaje-Ejemplo_de_maniobras_2019.pdf">Example types of drive</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Catalogo_Aparellaje-Completo_2019.pdf">Switchgear Catalog</a>

<a href="https://lescop.com/wp-content/uploads/2019/10/Manual_Instrucciones_SILE-U_WEB.pdf">User Manual SILE-U</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2365</post-id>	</item>
		<item>
		<title>PTE-4. Thermal Relay.</title>
		<link>https://lescop.com/en/catalogo/switches-disconnectors/pte-4-thermal-relay/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Wed, 07 Aug 2019 10:23:05 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/uncategorized/pte-4-thermal-relay/</guid>

					<description><![CDATA[<p style="text-align: justify;">The <strong>thermal relay PTE-4</strong> has been developed and adjusted to equip free-trip switch breakers free kick. The PTE-4 relays protect against constant weak overloads, not influencing variable loads or short duration overloads. Combined with high breaking capability fuses, sufficiently effective protections are achieved at minimal cost, for circuits where rated power is small, so very high short-circuit can rise. In these cases the price of a great power breaking capability can be very high compared to the rest of the installation.</p>
<p style="text-align: justify;"><strong>Characteristics:</strong></p>

<ul>
 	<li style="text-align: justify;">Rated frequency .............................................. 50 or 60 Hz</li>
 	<li style="text-align: justify;">Possible rated currents (In): 0.4 - 0.64 - 1 - 1.6 - 2 - 3 - 4 - 5 - 7 to 10 - 12.5 - 15 to 20 - 25 - 30 - 40 - 50 - 60 - 80 - 100 - 125 A</li>
 	<li style="text-align: justify;">Current regulation ........................................... In Ir = 1.6 In</li>
 	<li style="text-align: justify;">Tolerance on Ir ........................................................... + 10%</li>
 	<li style="text-align: justify;">Admissible Overcurrents:
<ul>
 	<li>For 0.02 seconds ................................................... 220 In.</li>
 	<li>For 1 second ............................................................. 30 In.</li>
 	<li>Permanent ................................................................ 1.8 In.</li>
</ul>
</li>
 	<li style="text-align: justify;">Consumption with rated current ................................ 4 VA</li>
 	<li style="text-align: justify;">Insulation voltage to ground .................................. 1000 V</li>
 	<li style="text-align: justify;">Test voltage (for 1 minute) ..................................... 3000 V</li>
 	<li style="text-align: justify;">Trip lever travel:
<ul>
 	<li>To disconnect ........................................................ 20 mm</li>
 	<li>To reset ................................................................... 21 mm</li>
</ul>
</li>
 	<li style="text-align: justify;">Tripping effort:
<ul>
 	<li>Starting position ..................................................... 530 gr</li>
 	<li>At the end of the travel .......................................... 1250gr</li>
</ul>
</li>
 	<li style="text-align: justify;">Reset effort (maximum) ........................................ 1500 gr</li>
 	<li style="text-align: justify;">Weight of the relay .....................................................940 gr</li>
</ul>
&#160;

<a href="https://lescop.com/wp-content/uploads/2020/02/RELE-PTE-4-Catalogo-Ingles.pdf">PTE-4 Catalog</a>]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;">The <strong>thermal relay PTE-4</strong> has been developed and adjusted to equip free-trip switch breakers free kick. The PTE-4 relays protect against constant weak overloads, not influencing variable loads or short duration overloads. Combined with high breaking capability fuses, sufficiently effective protections are achieved at minimal cost, for circuits where rated power is small, so very high short-circuit can rise. In these cases the price of a great power breaking capability can be very high compared to the rest of the installation.</p>
<p style="text-align: justify;"><strong>Characteristics:</strong></p>

<ul>
 	<li style="text-align: justify;">Rated frequency .............................................. 50 or 60 Hz</li>
 	<li style="text-align: justify;">Possible rated currents (In): 0.4 - 0.64 - 1 - 1.6 - 2 - 3 - 4 - 5 - 7 to 10 - 12.5 - 15 to 20 - 25 - 30 - 40 - 50 - 60 - 80 - 100 - 125 A</li>
 	<li style="text-align: justify;">Current regulation ........................................... In Ir = 1.6 In</li>
 	<li style="text-align: justify;">Tolerance on Ir ........................................................... + 10%</li>
 	<li style="text-align: justify;">Admissible Overcurrents:
<ul>
 	<li>For 0.02 seconds ................................................... 220 In.</li>
 	<li>For 1 second ............................................................. 30 In.</li>
 	<li>Permanent ................................................................ 1.8 In.</li>
</ul>
</li>
 	<li style="text-align: justify;">Consumption with rated current ................................ 4 VA</li>
 	<li style="text-align: justify;">Insulation voltage to ground .................................. 1000 V</li>
 	<li style="text-align: justify;">Test voltage (for 1 minute) ..................................... 3000 V</li>
 	<li style="text-align: justify;">Trip lever travel:
<ul>
 	<li>To disconnect ........................................................ 20 mm</li>
 	<li>To reset ................................................................... 21 mm</li>
</ul>
</li>
 	<li style="text-align: justify;">Tripping effort:
<ul>
 	<li>Starting position ..................................................... 530 gr</li>
 	<li>At the end of the travel .......................................... 1250gr</li>
</ul>
</li>
 	<li style="text-align: justify;">Reset effort (maximum) ........................................ 1500 gr</li>
 	<li style="text-align: justify;">Weight of the relay .....................................................940 gr</li>
</ul>
&#160;

<a href="https://lescop.com/wp-content/uploads/2020/02/RELE-PTE-4-Catalogo-Ingles.pdf">PTE-4 Catalog</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2407</post-id>	</item>
	</channel>
</rss>
