Measuring and/or protection current transformers. Indoor service up to 36 kV, insulated in epoxy resin.

      • Support type
      • Toroidal

Showing all 11 results

AKBF-0,6. Openable.
Insulation Voltage 0,72kV.
Toroidal Type.

LV Toroidal transformer for measuring and/or protecting up to 0,72 kV, used for measurement instruments, meters, relays and other similar devices. Designed to be used indoors.

The active part is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour. It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.

Openable design that facilitates its application in existing installations without the need to make modifications to it.

Possibility of installation in any position.

Manufactured in accordance with IEC 61869:1 and IEC 61869:2 standards.

 

AKBF-06 Catalog
User Manual

AKBF-0,6.
Insulation Voltage 0,72kV.
Toroidal Type.

LV Toroidal transformer for measuring and/or protecting up to 0,72 kV, used for measurement instruments, meters, relays and other similar devices.  Designed to be used indoors/outdoors.

The active part is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour. It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.

Possibility of installation in any position.

In this series of transformers, the dimensions depend both on the number of secondaries and on the burden and accuracy class of the secondary ones.

Manufactured in accordance with IEC 61869:1 and IEC 61869:2 standards.

 

AKBF-06 Catalog
User Manual
Accesories
Planes (.dwg)

AKH-01/02.
Insulation Voltage 0,72kV.
Homopolar Toroidal Type.

LV transformer for measuring and/or protecting up to 0,72 kV, used for measurement instruments, meters, relays and other similar devices. Designed to be used indoors.

The transformer AKH-01/02 has been designed to detect homopolar currents. Its carries out the summation of the three currents in an only core, giving as a result a secondary current proportional to the primary homopolar current.

The active part is occluded in class B polyurethane resin (according to IEC 60085 standard), in black colour. It provides high chemical resistance.

Manufactured in accordance with IEC 61869:1 and IEC 61869:2 standards.

 

AKH-01/02 Catalog
User Manual
Plane (.dwg)

AER-36.
Insulation Voltage 36kV.
Support Type.

HV Current transformer for measuring and/or protecting up to 36 kV, used for measurement instruments, meters, relays and other similar devices.  Designed to be used indoors.

The primary winding is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour.

It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.

Possibility of installation in any position.

Manufactured in accordance with IEC 61869:1 and IEC 61869:2 standards.

 

AER-36 Catalog
User Manual
Accesories Catalog
Plane (.dwg)

AER-24.
Insulation Voltage 24kV.
Support Type.

HV Current transformer for measuring and/or protecting up to 24 kV, used for measurement instruments, meters, relays and other similar devices. Designed to be used indoors.

The primary winding is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour.

It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.

Possibility of installation in any position.

Manufactured in accordance with IEC 61869:1 and IEC 61869:2 standards.

 

AER-24 Catalog
User Manual
Accesories Catalog
Plane (.dwg)

AED-36.
Insulation Voltage 36kV.
Support Type.

HV Current transformer for measuring and/or protecting up to 36 kV, used for measurement instruments, meters, relays and other similar devices. Designed to be used indoors.

The primary winding is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour.

It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.

Possibility of installation in any position.

Manufactured in accordance with IEC 61869:1 and IEC 61869:2 standards.

 

AED-36 Catalog
User Manual
Accesories Catalog
Plane (.dwg)

AED-24.
Insulation Voltage 24kV.
Support Type.

HV Current transformer for measuring and/or protecting up to 24 kV, used for measurement instruments, meters, relays and other similar devices.  Designed to be used indoors.

The primary winding is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour.

It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.

Possibility of installation in any position.

Manufactured in accordance with IEC 61869:1 and IEC 61869:2 standards.

 

AED-24 Catalog
User Manual
Accesories Catalog
Plane (.dwg)

AEC-36.
Insulation Voltage 36kV.
Support Type.

HV Current transformer for measuring and/or protecting up to 36 kV, used for measurement instruments, meters, relays and other similar devices. Designed to be used indoors.

The primary winding is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour.

It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.

Possibility of installation in any position.

Manufactured in accordance with IEC 61869:1 and IEC 61869:2 standards.

 

AEC-36 Catalog
User Manual
Accesories Catalog
Plane (.dwg)

AEC-24P.
Insulation Voltage 24kV.
Support Type.

HV Current transformer for measuring and/or protecting up to 24 kV, used for measurement instruments, meters, relays and other similar devices. Designed to be used indoors.

The primary winding is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour.

It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.

Possibility of installation in any position.

Manufactured in accordance with IEC 61869:1 and IEC 61869:2 standards.

 

AEC-24P Catalog
User Manual
Accesories Catalog
Plane (.dwg)

AEB-36.
Insulation Voltage 36kV.
Support Type.

HV Current transformer for measuring and/or protecting up to 36 kV, used for measurement instruments, meters, relays and other similar devices. Designed to be used indoors.

The primary winding is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour.

It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.

Possibility of installation in any position.

Manufactured in accordance with IEC 61869:1 and IEC 61869:2 standards.

 

AEB-36 Catalog
User Manual
Accesories Catalog
Plane (.dwg)

AEB-12/24.
Insulation Voltage 12 or 24kV.
Sopport Type.

HV Current transformer for measuring and/or protecting up to 12 or 24 kV, used for measurement instruments, meters, relays and other similar devices. Designed to be used indoors.

Primary switchable (series-parallel) or not, for double or simple transformation ratio. With one or two secondary windings.

The primary winding is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour. It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.

Possibility of installation in any position.

Manufactured in accordance with IEC 61869:1 and IEC 61869:2 standards.

 

AEB-12/24 Catalog
User Manual
Accesories Catalog
Plane (.dwg)