<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Tension Intérieur &#8211; Laboratorio Electrotécnico</title>
	<atom:link href="https://lescop.com/fr/productos/transformateurs/tension-interieur/feed/" rel="self" type="application/rss+xml" />
	<link>https://lescop.com/fr/</link>
	<description>Transformadores a medida, aparellaje eléctrico</description>
	<lastBuildDate>Mon, 01 Dec 2025 13:32:13 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.5</generator>
	<item>
		<title>VKPE-12.Tension D´Isolement 12kV.Connexion Phase-Terre.</title>
		<link>https://lescop.com/fr/catalogo/transformateurs/tension-interieur/vkpe-12-tension-disolement-12kv-connexion-phase-terre/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Thu, 08 Aug 2019 08:10:27 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/non%20classé/vkpe-12-tension-disolement-12kv-connexion-phase-terre/</guid>

					<description><![CDATA[<p style="text-align: JUSTIFY;">Transformateur de tension pour mesure et/ou protection de H.T. <strong>jusqu'à 12 kV</strong> destiné à l'alimentation d'instruments de mesure, compteurs, relais et appareils similaires. Il est conçu pour service intérieur.</p>
<p style="text-align: JUSTIFY;">L'enroulement primaire est enrobé en résine epoxy de couleur marron de classe d'isolement E. Le noyau el le/les secondaire/s sont en dehors de l'enveloppante. Grâce aux caractéristiques de cette conception il n'existe aucun risque de jet violent de fragments en cas d'explosion.</p>
<p style="text-align: JUSTIFY;">Le  transformateur types <strong>VKPE-12</strong> est un  modèles phase-terre, c'est à dire, monophasé, à un pôle, destinés à avoir une des bornes de l'enroulement primaire mise à la terre directement.</p>
<p style="text-align: JUSTIFY;">La gamme de transformateurs VKPE a été conçue en tenant compte de l'Environnement, car  nous n'avons pas utilisé ni d'huiles ni de gaz fluorés comme matériel isolant.</p>
<p style="text-align: JUSTIFY;">Ces transformateurs possèdent une grande résistance mécanique; Ils restent inaltérables aux attaques d'humidité, d'huile, de poussière et de la plupart des produits chimiques.</p>
<p style="text-align: JUSTIFY;">Fabriqué d'accord aux normes<strong> IEC 61869:1</strong> et <strong>IEC 61869:3.</strong></p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/VKPE-12_Catalogo_Frances_2019.pdf">Catalogue VKPE-12</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_fr_color-web.pdf"><span class="tlid-translation translation" lang="fr"><span class="" title="">Manuel d'utilisation</span></span></a>
<a href="https://lescop.com/wp-content/uploads/2019/10/Catálogo-Accesorios-Transformadores.pdf"><span class="tlid-translation translation" lang="fr"><span class="" title="">Catalogue Accessoires</span></span></a>
<a href="https://lescop.com/wp-content/uploads/2023/05/10525270.001-ESQUEMAS-TT-FASE-TIERRA.pdf">Schéma des connexions TT</a>
<a href="https://www.dropbox.com/s/rmsjyxx58lljndi/TT%20VKPE-12%20Laboratorio%20Electrot%C3%A9cnico.dwg?dl=0">Plan (.dwg)</a>]]></description>
										<content:encoded><![CDATA[<p style="text-align: JUSTIFY;">Transformateur de tension pour mesure et/ou protection de H.T. <strong>jusqu'à 12 kV</strong> destiné à l'alimentation d'instruments de mesure, compteurs, relais et appareils similaires. Il est conçu pour service intérieur.</p>
<p style="text-align: JUSTIFY;">L'enroulement primaire est enrobé en résine epoxy de couleur marron de classe d'isolement E. Le noyau el le/les secondaire/s sont en dehors de l'enveloppante. Grâce aux caractéristiques de cette conception il n'existe aucun risque de jet violent de fragments en cas d'explosion.</p>
<p style="text-align: JUSTIFY;">Le  transformateur types <strong>VKPE-12</strong> est un  modèles phase-terre, c'est à dire, monophasé, à un pôle, destinés à avoir une des bornes de l'enroulement primaire mise à la terre directement.</p>
<p style="text-align: JUSTIFY;">La gamme de transformateurs VKPE a été conçue en tenant compte de l'Environnement, car  nous n'avons pas utilisé ni d'huiles ni de gaz fluorés comme matériel isolant.</p>
<p style="text-align: JUSTIFY;">Ces transformateurs possèdent une grande résistance mécanique; Ils restent inaltérables aux attaques d'humidité, d'huile, de poussière et de la plupart des produits chimiques.</p>
<p style="text-align: JUSTIFY;">Fabriqué d'accord aux normes<strong> IEC 61869:1</strong> et <strong>IEC 61869:3.</strong></p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/VKPE-12_Catalogo_Frances_2019.pdf">Catalogue VKPE-12</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_fr_color-web.pdf"><span class="tlid-translation translation" lang="fr"><span class="" title="">Manuel d'utilisation</span></span></a>
<a href="https://lescop.com/wp-content/uploads/2019/10/Catálogo-Accesorios-Transformadores.pdf"><span class="tlid-translation translation" lang="fr"><span class="" title="">Catalogue Accessoires</span></span></a>
<a href="https://lescop.com/wp-content/uploads/2023/05/10525270.001-ESQUEMAS-TT-FASE-TIERRA.pdf">Schéma des connexions TT</a>
<a href="https://www.dropbox.com/s/rmsjyxx58lljndi/TT%20VKPE-12%20Laboratorio%20Electrot%C3%A9cnico.dwg?dl=0">Plan (.dwg)</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2611</post-id>	</item>
		<item>
		<title>VKPE-24.Tension D´Isolement 24kV.Connexion Phase-Terre.</title>
		<link>https://lescop.com/fr/catalogo/transformateurs/tension-interieur/vkpe-24-tension-disolement-24kv-connexion-phase-terre/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Thu, 08 Aug 2019 08:21:15 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/non%20classé/vkpe-24-tension-disolement-24kv-connexion-phase-terre/</guid>

					<description><![CDATA[<p style="text-align: justify;">Transformateur de tension pour mesure et/ou protection de H.T. <strong>jusqu'à 24 kV</strong> destiné à l'alimentation d'instruments de mesure, compteurs, relais et appareils similaires. Il est conçu pour service intérieur.</p>
<p style="text-align: justify;">L'enroulement primaire est enrobé en résine epoxy de couleur marron de classe d'isolement E. Le noyau el le/les secondaire/s sont en dehors de l'enveloppante. Grâce aux caractéristiques de cette conception il n'existe aucun risque de jet violent de fragments en cas d'explosion.</p>
<p style="text-align: justify;">Le transformateur types <strong>VKPE-24</strong> est un modèles phase-terre, c'est à dire, monophasé, à un pôle, destinés à avoir une des bornes de l'enroulement primaire mise à la terre directement.</p>
<p style="text-align: justify;">La gamme de transformateurs VKPE a été conçue en tenant compte de l'Environnement, car  nous n'avons pas utilisé ni d'huiles ni de gaz fluorés comme matériel isolant.</p>
<p style="text-align: justify;">Ces transformateurs possèdent une grande résistance mécanique; Ils restent inaltérables aux attaques d'humidité, d'huile, de poussière et de la plupart des produits chimiques.</p>
<p style="text-align: justify;">Fabriqué d'accord aux normes <strong>IEC 61869:1</strong> et <strong>IEC 61869:3.</strong></p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/VKPE-24_Catalogo_Frances_2019.pdf">Catalogue VKPE-24</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_fr_color-web.pdf"><span class="tlid-translation translation" lang="fr"><span class="" title="">Manuel d'utilisation</span></span></a>
<a href="https://lescop.com/wp-content/uploads/2019/10/Catálogo-Accesorios-Transformadores.pdf"><span class="tlid-translation translation" lang="fr"><span class="" title="">Catalogue Accessoires</span></span></a>
<a href="https://lescop.com/wp-content/uploads/2023/05/10525270.001-ESQUEMAS-TT-FASE-TIERRA.pdf">Schéma des connexions TT</a>
<a href="https://www.dropbox.com/s/c54rpjqoeoax1nt/TT%20VKPE-24%20Laboratorio%20Electrot%C3%A9cnico.dwg?dl=0">Plan (.dwg)</a>]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;">Transformateur de tension pour mesure et/ou protection de H.T. <strong>jusqu'à 24 kV</strong> destiné à l'alimentation d'instruments de mesure, compteurs, relais et appareils similaires. Il est conçu pour service intérieur.</p>
<p style="text-align: justify;">L'enroulement primaire est enrobé en résine epoxy de couleur marron de classe d'isolement E. Le noyau el le/les secondaire/s sont en dehors de l'enveloppante. Grâce aux caractéristiques de cette conception il n'existe aucun risque de jet violent de fragments en cas d'explosion.</p>
<p style="text-align: justify;">Le transformateur types <strong>VKPE-24</strong> est un modèles phase-terre, c'est à dire, monophasé, à un pôle, destinés à avoir une des bornes de l'enroulement primaire mise à la terre directement.</p>
<p style="text-align: justify;">La gamme de transformateurs VKPE a été conçue en tenant compte de l'Environnement, car  nous n'avons pas utilisé ni d'huiles ni de gaz fluorés comme matériel isolant.</p>
<p style="text-align: justify;">Ces transformateurs possèdent une grande résistance mécanique; Ils restent inaltérables aux attaques d'humidité, d'huile, de poussière et de la plupart des produits chimiques.</p>
<p style="text-align: justify;">Fabriqué d'accord aux normes <strong>IEC 61869:1</strong> et <strong>IEC 61869:3.</strong></p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/VKPE-24_Catalogo_Frances_2019.pdf">Catalogue VKPE-24</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_fr_color-web.pdf"><span class="tlid-translation translation" lang="fr"><span class="" title="">Manuel d'utilisation</span></span></a>
<a href="https://lescop.com/wp-content/uploads/2019/10/Catálogo-Accesorios-Transformadores.pdf"><span class="tlid-translation translation" lang="fr"><span class="" title="">Catalogue Accessoires</span></span></a>
<a href="https://lescop.com/wp-content/uploads/2023/05/10525270.001-ESQUEMAS-TT-FASE-TIERRA.pdf">Schéma des connexions TT</a>
<a href="https://www.dropbox.com/s/c54rpjqoeoax1nt/TT%20VKPE-24%20Laboratorio%20Electrot%C3%A9cnico.dwg?dl=0">Plan (.dwg)</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2612</post-id>	</item>
		<item>
		<title>VKPE-36.Tension D´Isolement 36kV.Connexion Phase-Terre.</title>
		<link>https://lescop.com/fr/catalogo/transformateurs/tension-interieur/vkpe-36-tension-disolement-36kv-connexion-phase-terre/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Thu, 08 Aug 2019 08:27:43 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/non%20classé/vkpe-36-tension-disolement-36kv-connexion-phase-terre/</guid>

					<description><![CDATA[<p style="text-align: justify;">Transformateur de tension pour mesure et/ou protection de H.T.<strong> jusqu'à 36 kV</strong> destiné à l'alimentation d'instruments de mesure, compteurs, relais et appareils similaires. Il est conçu pour service intérieur.</p>
<p style="text-align: justify;">L'enroulement primaire est enrobé en résine epoxy de couleur marron de classe d'isolement E. Le noyau el le/les secondaire/s sont en dehors de l'enveloppante. Grâce aux caractéristiques de cette conception il n'existe aucun risque de jet violent de fragments en cas d'explosion.</p>
<p style="text-align: justify;">Le transformateur types <strong>VKPE-36</strong> est un modèles phase-terre, c'est à dire, monophasé, à un pôle, destinés à avoir une des bornes de l'enroulement primaire mise à la terre directement.</p>
<p style="text-align: justify;">La gamme de transformateurs VKPE a été conçue en tenant compte de l'Environnement, car  nous n'avons pas utilisé ni d'huiles ni de gaz fluorés comme matériel isolant.</p>
<p style="text-align: justify;">Ces transformateurs possèdent une grande résistance mécanique; Ils restent inaltérables aux attaques d'humidité, d'huile, de poussière et de la plupart des produits chimiques.</p>
<p style="text-align: justify;">Fabriqué d'accord aux normes <strong>IEC 61869:1</strong> et <strong>IEC 61869:3</strong>.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/VKPE-36_Catalogo_Frances_2019.pdf">Catalogue VKPE-36</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_fr_color-web.pdf"><span class="tlid-translation translation" lang="fr"><span class="" title="">Manuel d'utilisation</span></span></a>
<a href="https://lescop.com/wp-content/uploads/2019/10/Catálogo-Accesorios-Transformadores.pdf"><span class="tlid-translation translation" lang="fr"><span class="" title="">Catalogue Accessoires</span></span></a>
<a href="https://lescop.com/wp-content/uploads/2023/05/10525270.001-ESQUEMAS-TT-FASE-TIERRA.pdf">Schéma des connexions TT</a>
<a href="https://www.dropbox.com/s/pmq38j09abn1gwg/TT%20VKPE-36%20Laboratorio%20Electrot%C3%A9cnico.dwg?dl=0">Plan (.dwg)</a>]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;">Transformateur de tension pour mesure et/ou protection de H.T.<strong> jusqu'à 36 kV</strong> destiné à l'alimentation d'instruments de mesure, compteurs, relais et appareils similaires. Il est conçu pour service intérieur.</p>
<p style="text-align: justify;">L'enroulement primaire est enrobé en résine epoxy de couleur marron de classe d'isolement E. Le noyau el le/les secondaire/s sont en dehors de l'enveloppante. Grâce aux caractéristiques de cette conception il n'existe aucun risque de jet violent de fragments en cas d'explosion.</p>
<p style="text-align: justify;">Le transformateur types <strong>VKPE-36</strong> est un modèles phase-terre, c'est à dire, monophasé, à un pôle, destinés à avoir une des bornes de l'enroulement primaire mise à la terre directement.</p>
<p style="text-align: justify;">La gamme de transformateurs VKPE a été conçue en tenant compte de l'Environnement, car  nous n'avons pas utilisé ni d'huiles ni de gaz fluorés comme matériel isolant.</p>
<p style="text-align: justify;">Ces transformateurs possèdent une grande résistance mécanique; Ils restent inaltérables aux attaques d'humidité, d'huile, de poussière et de la plupart des produits chimiques.</p>
<p style="text-align: justify;">Fabriqué d'accord aux normes <strong>IEC 61869:1</strong> et <strong>IEC 61869:3</strong>.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/VKPE-36_Catalogo_Frances_2019.pdf">Catalogue VKPE-36</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_fr_color-web.pdf"><span class="tlid-translation translation" lang="fr"><span class="" title="">Manuel d'utilisation</span></span></a>
<a href="https://lescop.com/wp-content/uploads/2019/10/Catálogo-Accesorios-Transformadores.pdf"><span class="tlid-translation translation" lang="fr"><span class="" title="">Catalogue Accessoires</span></span></a>
<a href="https://lescop.com/wp-content/uploads/2023/05/10525270.001-ESQUEMAS-TT-FASE-TIERRA.pdf">Schéma des connexions TT</a>
<a href="https://www.dropbox.com/s/pmq38j09abn1gwg/TT%20VKPE-36%20Laboratorio%20Electrot%C3%A9cnico.dwg?dl=0">Plan (.dwg)</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2613</post-id>	</item>
		<item>
		<title>VKE-24.Tension D´Isolement 24kV.Connexion Phase-Terre. Type Embrochable.</title>
		<link>https://lescop.com/fr/catalogo/transformateurs/tension-interieur/vke-24-type-embrochable-tension-disolement-24kv-connexion-phase-terre/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Thu, 08 Aug 2019 07:53:22 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/non%20classé/vke-24-type-embrochable-tension-disolement-24kv-connexion-phase-terre/</guid>

					<description><![CDATA[<p style="text-align: justify;">Transformateur de tension pour mesure et/ou protection de H.T. <strong>jusqu'à 24 kV</strong>, conçu pour être installé dans des cellules de haute tension isolées à gaz.</p>
<p style="text-align: justify;">Le modèle <strong>VKE-24</strong> permet le branchement dans le primaire à l'aide d'un <strong>terminal embrochable</strong> conçu en conformité à la <strong>norme UNE-EN 50181</strong>.</p>
<p style="text-align: justify;">Une enveloppante métallique sur le corps de résine protège le transformateur, permettant ainsi son montage sans distance de sécurité entre les autres transformateurs, car la surface du transformateur est mise à la terre, ce que permet la meilleur optimisation de l'espace.</p>
<p style="text-align: justify;">Sur commande, on peut aussi fournir ce transformateur sans la protection métallique, mais alors il faudrait l'installer en cellules sans isolement à l'SF6, en respectant les distances de sécurité correspondantes au niveau d'isolement.</p>
<p style="text-align: justify;">L'enroulement primaire est enrobé en résine epoxy de couleur marron de classe d'isolement E. Le noyau el le/les secondaire/s sont en dehors de l'enveloppante. Grâce aux caractéristiques de cette conception il n'existe aucun risque de jet violent de fragments en cas d'explosion.</p>
<p style="text-align: justify;">Possibilité de montage dans n'importe quelle position.</p>
<p style="text-align: justify;">Fabriqué d'accord aux normes <strong>IEC 61869:1</strong> et <strong>IEC 61869:3.</strong></p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/VKE-24_Catalogo_Frances_2019.pdf">Catalogue VKE-24</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_fr_color-web.pdf">Manuel d'utilisation</a>
<a href="https://lescop.com/wp-content/uploads/2023/05/10525270.001-ESQUEMAS-TT-FASE-TIERRA.pdf">Schéma des connexions TT</a>
<a href="https://www.dropbox.com/s/wv3r4ssz71hds96/TT%20VKE-24%20Laboratorio%20Electrot%C3%A9cnico.dwg?dl=0">Plan (.dwg)</a>]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;">Transformateur de tension pour mesure et/ou protection de H.T. <strong>jusqu'à 24 kV</strong>, conçu pour être installé dans des cellules de haute tension isolées à gaz.</p>
<p style="text-align: justify;">Le modèle <strong>VKE-24</strong> permet le branchement dans le primaire à l'aide d'un <strong>terminal embrochable</strong> conçu en conformité à la <strong>norme UNE-EN 50181</strong>.</p>
<p style="text-align: justify;">Une enveloppante métallique sur le corps de résine protège le transformateur, permettant ainsi son montage sans distance de sécurité entre les autres transformateurs, car la surface du transformateur est mise à la terre, ce que permet la meilleur optimisation de l'espace.</p>
<p style="text-align: justify;">Sur commande, on peut aussi fournir ce transformateur sans la protection métallique, mais alors il faudrait l'installer en cellules sans isolement à l'SF6, en respectant les distances de sécurité correspondantes au niveau d'isolement.</p>
<p style="text-align: justify;">L'enroulement primaire est enrobé en résine epoxy de couleur marron de classe d'isolement E. Le noyau el le/les secondaire/s sont en dehors de l'enveloppante. Grâce aux caractéristiques de cette conception il n'existe aucun risque de jet violent de fragments en cas d'explosion.</p>
<p style="text-align: justify;">Possibilité de montage dans n'importe quelle position.</p>
<p style="text-align: justify;">Fabriqué d'accord aux normes <strong>IEC 61869:1</strong> et <strong>IEC 61869:3.</strong></p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/VKE-24_Catalogo_Frances_2019.pdf">Catalogue VKE-24</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_fr_color-web.pdf">Manuel d'utilisation</a>
<a href="https://lescop.com/wp-content/uploads/2023/05/10525270.001-ESQUEMAS-TT-FASE-TIERRA.pdf">Schéma des connexions TT</a>
<a href="https://www.dropbox.com/s/wv3r4ssz71hds96/TT%20VKE-24%20Laboratorio%20Electrot%C3%A9cnico.dwg?dl=0">Plan (.dwg)</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2609</post-id>	</item>
		<item>
		<title>VKE-36.Tension D´Isolement 36kV.Connexion Phase-Terre. Type Embrochable.</title>
		<link>https://lescop.com/fr/catalogo/transformateurs/tension-interieur/vke-36-type-embrochable-tension-disolement-36kv-connexion-phase-terre/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Thu, 08 Aug 2019 08:02:32 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/non%20classé/vke-36-type-embrochable-tension-disolement-36kv-connexion-phase-terre/</guid>

					<description><![CDATA[<p style="text-align: justify;">Transformateur de tension pour mesure et/ou protection de H.T. <strong>jusqu'à 36 kV</strong>, conçu pour être installé dans des cellules de haute tension isolées à gaz.</p>
<p style="text-align: justify;">Le modèle <strong>VKE-36</strong> permet le branchement dans le primaire à l'aide d'un <strong>terminal embrochable</strong> conçu en conformité à la <strong>norme UNE-EN 50181</strong>.</p>
<p style="text-align: justify;">Une enveloppante métallique sur le corps de résine protège le transformateur, permettant ainsi son montage sans distance de sécurité entre les autres transformateurs, car la surface du transformateur est mise à la terre, ce que permet la meilleur optimisation de l'espace.</p>
<p style="text-align: justify;">Sur commande, on peut aussi fournir ce transformateur sans la protection métallique, mais alors il faudrait l'installer en cellules sans isolement à l'SF6, en respectant les distances de sécurité correspondantes au niveau d'isolement.</p>
<p style="text-align: justify;">L'enroulement primaire est enrobé en résine epoxy de couleur marron de classe d'isolement E. Le noyau el le/les secondaire/s sont en dehors de l'enveloppante. Grâce aux caractéristiques de cette conception il n'existe aucun risque de jet violent de fragments en cas d'explosion.</p>
<p style="text-align: justify;">Possibilité de montage dans n'importe quelle position.</p>
<p style="text-align: justify;">Fabriqué d'accord aux normes <strong>IEC 61869:1</strong> et <strong>IEC 61869:3.</strong></p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/VKE-36_Catalogo_Frances_2019.pdf">Catalogue VKE-36</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_fr_color-web.pdf"><span class="tlid-translation translation" lang="fr"><span class="" title="">Manuel d'utilisation</span></span></a>
<a href="https://lescop.com/wp-content/uploads/2023/05/10525270.001-ESQUEMAS-TT-FASE-TIERRA.pdf">Schéma des connexions TT</a>
<a href="https://www.dropbox.com/s/4e3tk6vm5y7jcrw/TT%20VKE-36%20Laboratorio%20Electrot%C3%A9cnico.dwg?dl=0">Plan (.dwg)</a>]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;">Transformateur de tension pour mesure et/ou protection de H.T. <strong>jusqu'à 36 kV</strong>, conçu pour être installé dans des cellules de haute tension isolées à gaz.</p>
<p style="text-align: justify;">Le modèle <strong>VKE-36</strong> permet le branchement dans le primaire à l'aide d'un <strong>terminal embrochable</strong> conçu en conformité à la <strong>norme UNE-EN 50181</strong>.</p>
<p style="text-align: justify;">Une enveloppante métallique sur le corps de résine protège le transformateur, permettant ainsi son montage sans distance de sécurité entre les autres transformateurs, car la surface du transformateur est mise à la terre, ce que permet la meilleur optimisation de l'espace.</p>
<p style="text-align: justify;">Sur commande, on peut aussi fournir ce transformateur sans la protection métallique, mais alors il faudrait l'installer en cellules sans isolement à l'SF6, en respectant les distances de sécurité correspondantes au niveau d'isolement.</p>
<p style="text-align: justify;">L'enroulement primaire est enrobé en résine epoxy de couleur marron de classe d'isolement E. Le noyau el le/les secondaire/s sont en dehors de l'enveloppante. Grâce aux caractéristiques de cette conception il n'existe aucun risque de jet violent de fragments en cas d'explosion.</p>
<p style="text-align: justify;">Possibilité de montage dans n'importe quelle position.</p>
<p style="text-align: justify;">Fabriqué d'accord aux normes <strong>IEC 61869:1</strong> et <strong>IEC 61869:3.</strong></p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/VKE-36_Catalogo_Frances_2019.pdf">Catalogue VKE-36</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_fr_color-web.pdf"><span class="tlid-translation translation" lang="fr"><span class="" title="">Manuel d'utilisation</span></span></a>
<a href="https://lescop.com/wp-content/uploads/2023/05/10525270.001-ESQUEMAS-TT-FASE-TIERRA.pdf">Schéma des connexions TT</a>
<a href="https://www.dropbox.com/s/4e3tk6vm5y7jcrw/TT%20VKE-36%20Laboratorio%20Electrot%C3%A9cnico.dwg?dl=0">Plan (.dwg)</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2610</post-id>	</item>
		<item>
		<title>ARM TT. Armoire de résistances de charge pour TT.</title>
		<link>https://lescop.com/fr/catalogo/transformateurs/tension-exterieur/arm-armoire-de-resistances/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Fri, 02 Aug 2019 15:02:32 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/non%20classé/arm2-armoire-de-resistances/</guid>

					<description><![CDATA[<p data-path-to-node="4">L'<b>ARM TT</b> est une armoire de résistances de charge conçue pour les <b>transformateurs de tension (TT)</b>. Elle se compose de <b>un à trois groupes de 3 résistances</b>, de leur bornier respectif et d'un <b>disjoncteur magnétothermique de 2 A</b>. Ces composants sont logés dans une armoire métallique disposant d'une ventilation (naturelle ou forcée, selon les spécifications demandées), avec les connexions protégées par un <b>capot plombable</b>.</p>
<p data-path-to-node="5">L'armoire est fabriquée en tôle d'acier (laqué ou inoxydable, selon les exigences) et dispose d'une <b>serrure à double panneton de 3 mm</b> actionnée par batteuse, scellée au moyen d'une vis à fente pour empêcher toute <b>manipulation</b> non autorisée.</p>
<p data-path-to-node="6">Elle est conçue pour un <b>service intérieur</b>. Sur demande, elle peut être fabriquée pour un service extérieur, ainsi que dans diverses autres configurations.</p>
<p data-path-to-node="7">Sa fonction est de consommer la puissance nécessaire pour assurer que le transformateur fonctionne à un minimum de <b>25 % de sa charge de précision nominale</b>. Cela s'applique dans les cas où les charges connectées à l'appareil (compteurs, relais, etc.) n'atteignent pas le seuil minimal requis pour garantir la précision de la mesure.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2021/05/CF.ARM_.-Francés-ARM.pdf">Catalogue ARM</a>
<a href="https://lescop.com/wp-content/uploads/2020/03/User-Manual-ARM150-07-02-2020-Web.pdf"><span class="tlid-translation translation" lang="fr"><span class="" title="">Manuel d'instructions</span></span> ARM</a>]]></description>
										<content:encoded><![CDATA[<p data-path-to-node="4">L'<b>ARM TT</b> est une armoire de résistances de charge conçue pour les <b>transformateurs de tension (TT)</b>. Elle se compose de <b>un à trois groupes de 3 résistances</b>, de leur bornier respectif et d'un <b>disjoncteur magnétothermique de 2 A</b>. Ces composants sont logés dans une armoire métallique disposant d'une ventilation (naturelle ou forcée, selon les spécifications demandées), avec les connexions protégées par un <b>capot plombable</b>.</p>
<p data-path-to-node="5">L'armoire est fabriquée en tôle d'acier (laqué ou inoxydable, selon les exigences) et dispose d'une <b>serrure à double panneton de 3 mm</b> actionnée par batteuse, scellée au moyen d'une vis à fente pour empêcher toute <b>manipulation</b> non autorisée.</p>
<p data-path-to-node="6">Elle est conçue pour un <b>service intérieur</b>. Sur demande, elle peut être fabriquée pour un service extérieur, ainsi que dans diverses autres configurations.</p>
<p data-path-to-node="7">Sa fonction est de consommer la puissance nécessaire pour assurer que le transformateur fonctionne à un minimum de <b>25 % de sa charge de précision nominale</b>. Cela s'applique dans les cas où les charges connectées à l'appareil (compteurs, relais, etc.) n'atteignent pas le seuil minimal requis pour garantir la précision de la mesure.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2021/05/CF.ARM_.-Francés-ARM.pdf">Catalogue ARM</a>
<a href="https://lescop.com/wp-content/uploads/2020/03/User-Manual-ARM150-07-02-2020-Web.pdf"><span class="tlid-translation translation" lang="fr"><span class="" title="">Manuel d'instructions</span></span> ARM</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2593</post-id>	</item>
	</channel>
</rss>
