<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Indoor Current &#8211; Laboratorio Electrotécnico</title>
	<atom:link href="https://lescop.com/en/productos/instrument-transformers/indoor-current/feed/" rel="self" type="application/rss+xml" />
	<link>https://lescop.com/en/</link>
	<description>Transformadores a medida, aparellaje eléctrico</description>
	<lastBuildDate>Mon, 01 Dec 2025 13:13:28 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>
	<item>
		<title>ARM. Resistances Cabinet.</title>
		<link>https://lescop.com/en/catalogo/instrument-transformers/indoor-current/arm-resistances-cabinet-copia-copia-copia/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Mon, 13 Jun 2022 12:30:50 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.com/?post_type=product&#038;p=9099</guid>

					<description><![CDATA[<p style="text-align: justify;"><span lang="EN-GB">The load resistors cabinet <strong>ARM</strong> consists of a resistance box, a non-sealable terminal strip and a 2A circuit breaker, located in a metal cabinet with ventilation and connections protected by a sealable cover to prevent tampering.</span></p>
<p style="text-align: justify;"><span lang="EN-GB">Box load resistors, is comprised of three load resistors contained in a metal box with surface treatment to prevent corrosion and to evacuate the heat.</span></p>
<p style="text-align: justify;"><span lang="EN-GB">It is designed for indoor use. </span>On request it can be manufactured for outdoor service and with different configurations.</p>
<p style="text-align: justify;">Its function is to <strong>consume the necessary power for the transformer to work at least at 25% of the accuracy burden</strong> in cases where the loads connected to the unit (meters, relays,etc.) do not reach the minimum necessary to guaranteed measurement accuracy.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2021/05/CI.ARM_.-Inglés-ARM.pdf" target="_blank" rel="noopener noreferrer">ARM Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/03/User-Manual-ARM150-07-02-2020-Web.pdf">User Manual ARM</a>]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;"><span lang="EN-GB">The load resistors cabinet <strong>ARM</strong> consists of a resistance box, a non-sealable terminal strip and a 2A circuit breaker, located in a metal cabinet with ventilation and connections protected by a sealable cover to prevent tampering.</span></p>
<p style="text-align: justify;"><span lang="EN-GB">Box load resistors, is comprised of three load resistors contained in a metal box with surface treatment to prevent corrosion and to evacuate the heat.</span></p>
<p style="text-align: justify;"><span lang="EN-GB">It is designed for indoor use. </span>On request it can be manufactured for outdoor service and with different configurations.</p>
<p style="text-align: justify;">Its function is to <strong>consume the necessary power for the transformer to work at least at 25% of the accuracy burden</strong> in cases where the loads connected to the unit (meters, relays,etc.) do not reach the minimum necessary to guaranteed measurement accuracy.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2021/05/CI.ARM_.-Inglés-ARM.pdf" target="_blank" rel="noopener noreferrer">ARM Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/03/User-Manual-ARM150-07-02-2020-Web.pdf">User Manual ARM</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">9099</post-id>	</item>
		<item>
		<title>ARM TT+TI. Load resistor cabinet for a set of VT &#038; CT.</title>
		<link>https://lescop.com/en/catalogo/instrument-transformers/indoor-current/arm-resistances-cabinet-copia-copia/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Mon, 13 Jun 2022 12:14:39 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.com/?post_type=product&#038;p=9091</guid>

					<description><![CDATA[<p data-path-to-node="4">The <b>ARM TT+TI</b> is a load resistor cabinet designed for a set of voltage and current transformers (VT &#38; CT). It comprises a slotted enclosure containing 3 resistors (current circuit), a group of 3 resistors (voltage circuit), their respective <b>terminal block</b>, and a <b>2 A Miniature Circuit Breaker (MCB)</b>. These components are housed in a metal cabinet featuring ventilation (natural or forced, depending on the requested specifications), with connections protected by a <b>sealable cover</b>.</p>
<p data-path-to-node="5">The cabinet is manufactured from sheet steel (lacquered or stainless, according to requirements) and features a <b>3 mm double-bit lock</b> operated by a cam, sealed via a slotted screw to prevent unauthorized tampering.</p>
<p data-path-to-node="6">It is designed for <b>indoor service</b>. Upon request, it can be manufactured for outdoor service, as well as in various other configurations.</p>
<p data-path-to-node="7">Its function is to consume the necessary power to ensure the transformers operate at a minimum of <b>25% of their rated accuracy burden</b>. This applies in cases where the loads connected to the device (meters, relays, etc.) do not reach the minimum threshold required to guarantee measurement accuracy.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2021/05/CI.ARM_.-Inglés-ARM.pdf" target="_blank" rel="noopener noreferrer">ARM Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/03/User-Manual-ARM150-07-02-2020-Web.pdf">User Manual ARM</a>]]></description>
										<content:encoded><![CDATA[<p data-path-to-node="4">The <b>ARM TT+TI</b> is a load resistor cabinet designed for a set of voltage and current transformers (VT &#38; CT). It comprises a slotted enclosure containing 3 resistors (current circuit), a group of 3 resistors (voltage circuit), their respective <b>terminal block</b>, and a <b>2 A Miniature Circuit Breaker (MCB)</b>. These components are housed in a metal cabinet featuring ventilation (natural or forced, depending on the requested specifications), with connections protected by a <b>sealable cover</b>.</p>
<p data-path-to-node="5">The cabinet is manufactured from sheet steel (lacquered or stainless, according to requirements) and features a <b>3 mm double-bit lock</b> operated by a cam, sealed via a slotted screw to prevent unauthorized tampering.</p>
<p data-path-to-node="6">It is designed for <b>indoor service</b>. Upon request, it can be manufactured for outdoor service, as well as in various other configurations.</p>
<p data-path-to-node="7">Its function is to consume the necessary power to ensure the transformers operate at a minimum of <b>25% of their rated accuracy burden</b>. This applies in cases where the loads connected to the device (meters, relays, etc.) do not reach the minimum threshold required to guarantee measurement accuracy.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2021/05/CI.ARM_.-Inglés-ARM.pdf" target="_blank" rel="noopener noreferrer">ARM Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/03/User-Manual-ARM150-07-02-2020-Web.pdf">User Manual ARM</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">9091</post-id>	</item>
		<item>
		<title>ARM TI. Load resistor cabinet for CT.</title>
		<link>https://lescop.com/en/catalogo/instrument-transformers/indoor-current/arm-resistances-cabinet-copia/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Mon, 13 Jun 2022 11:45:02 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.com/?post_type=product&#038;p=9083</guid>

					<description><![CDATA[<p data-path-to-node="4">The <b>ARM TI</b> is a load resistor cabinet designed for <b>Current Transformers (CT)</b>. It comprises a slotted enclosure containing 3 resistors and their respective terminal block, housed in a metal cabinet featuring ventilation (natural or forced, depending on the requested specifications), with connections protected by a <b>sealable cover</b>.</p>
<p data-path-to-node="5">The cabinet is manufactured from sheet steel (lacquered or stainless, according to requirements) and features a <b>3 mm double-bit lock</b> operated by a cam, sealed via a slotted screw to prevent unauthorized <b>tampering</b>.</p>
<p data-path-to-node="6">It is designed for <b>indoor service</b>. Upon request, it can be manufactured for outdoor service, as well as in various other configurations.</p>
<p data-path-to-node="7">Its function is to consume the necessary power to ensure the transformer operates <b>between 25% and 100% of its rated accuracy burden</b>. This applies in cases where the loads connected to the device (meters, relays, etc.) do not reach the minimum threshold required to guarantee measurement accuracy.</p>
<a href="https://lescop.com/wp-content/uploads/2021/05/CI.ARM_.-Inglés-ARM.pdf" target="_blank" rel="noopener noreferrer">ARM Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/03/User-Manual-ARM150-07-02-2020-Web.pdf">User Manual ARM</a>]]></description>
										<content:encoded><![CDATA[<p data-path-to-node="4">The <b>ARM TI</b> is a load resistor cabinet designed for <b>Current Transformers (CT)</b>. It comprises a slotted enclosure containing 3 resistors and their respective terminal block, housed in a metal cabinet featuring ventilation (natural or forced, depending on the requested specifications), with connections protected by a <b>sealable cover</b>.</p>
<p data-path-to-node="5">The cabinet is manufactured from sheet steel (lacquered or stainless, according to requirements) and features a <b>3 mm double-bit lock</b> operated by a cam, sealed via a slotted screw to prevent unauthorized <b>tampering</b>.</p>
<p data-path-to-node="6">It is designed for <b>indoor service</b>. Upon request, it can be manufactured for outdoor service, as well as in various other configurations.</p>
<p data-path-to-node="7">Its function is to consume the necessary power to ensure the transformer operates <b>between 25% and 100% of its rated accuracy burden</b>. This applies in cases where the loads connected to the device (meters, relays, etc.) do not reach the minimum threshold required to guarantee measurement accuracy.</p>
<a href="https://lescop.com/wp-content/uploads/2021/05/CI.ARM_.-Inglés-ARM.pdf" target="_blank" rel="noopener noreferrer">ARM Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/03/User-Manual-ARM150-07-02-2020-Web.pdf">User Manual ARM</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">9083</post-id>	</item>
		<item>
		<title>AKBF-0,6. Openable.Insulation Voltage 0,72kV.Toroidal Type.</title>
		<link>https://lescop.com/en/catalogo/instrument-transformers/indoor-current/akbf-0-6-insulation-voltage-072-kv-toroidal-type-2/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Mon, 25 Nov 2019 07:21:17 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/?post_type=product&#038;p=5406</guid>

					<description><![CDATA[<p style="font-weight: 400; text-align: justify;">LV Toroidal transformer for measuring and/or protecting <strong>up to 0,72 kV</strong>, used for measurement instruments, meters, relays and other similar devices. Designed to be used indoors.</p>
<p style="font-weight: 400; text-align: justify;">The active part is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour. It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.</p>
<p style="text-align: justify;"><span title=""><strong>Openable design</strong> that facilitates its application in existing installations without the need to make modifications to it.</span></p>
<p style="font-weight: 400; text-align: justify;">Possibility of installation in any position.</p>
<p style="font-weight: 400; text-align: justify;">Manufactured in accordance with <strong>IEC 61869:1</strong> and <strong>IEC 61869:2</strong> standards.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/AKBF-06_Catalogo_Castellano_2019.pdf">AKBF-06 Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_en_color-web.pdf">User Manual</a>]]></description>
										<content:encoded><![CDATA[<p style="font-weight: 400; text-align: justify;">LV Toroidal transformer for measuring and/or protecting <strong>up to 0,72 kV</strong>, used for measurement instruments, meters, relays and other similar devices. Designed to be used indoors.</p>
<p style="font-weight: 400; text-align: justify;">The active part is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour. It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.</p>
<p style="text-align: justify;"><span title=""><strong>Openable design</strong> that facilitates its application in existing installations without the need to make modifications to it.</span></p>
<p style="font-weight: 400; text-align: justify;">Possibility of installation in any position.</p>
<p style="font-weight: 400; text-align: justify;">Manufactured in accordance with <strong>IEC 61869:1</strong> and <strong>IEC 61869:2</strong> standards.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/AKBF-06_Catalogo_Castellano_2019.pdf">AKBF-06 Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_en_color-web.pdf">User Manual</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">5406</post-id>	</item>
		<item>
		<title>AKBF-0,6.Insulation Voltage 0,72kV.Toroidal Type.</title>
		<link>https://lescop.com/en/catalogo/instrument-transformers/indoor-current/akbf-0-6-insulation-voltage-072-kv-toroidal-type/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Fri, 09 Aug 2019 07:05:50 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/uncategorized/akbf-0-6-insulation-voltage-072-kv-toroidal-type/</guid>

					<description><![CDATA[<p style="font-weight: 400; text-align: justify;">LV Toroidal transformer for measuring and/or protecting <strong>up to 0,72 kV</strong>, used for measurement instruments, meters, relays and other similar devices.  Designed to be used indoors/outdoors.</p>
<p style="font-weight: 400; text-align: justify;">The active part is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour. It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.</p>
<p style="font-weight: 400; text-align: justify;">Possibility of installation in any position.</p>
<p style="font-weight: 400; text-align: justify;">In this series of transformers, the dimensions depend both on the number of secondaries and on the burden and accuracy class of the secondary ones.</p>
<p style="font-weight: 400; text-align: justify;">Manufactured in accordance with <strong>IEC 61869:1</strong> and <strong>IEC 61869:2</strong> standards.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/AKBF-06_Catalogo_Castellano_2019.pdf">AKBF-06 Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_en_color-web.pdf">User Manual</a>
<a href="https://lescop.com/wp-content/uploads/2019/10/Catálogo-Accesorios-Transformadores.pdf">Accesories</a>
<a href="https://www.dropbox.com/sh/42n8v7i5jsofimq/AADhj8Xag6lV8BjB-Qi6BmW4a?dl=0">Planes (.dwg)</a>]]></description>
										<content:encoded><![CDATA[<p style="font-weight: 400; text-align: justify;">LV Toroidal transformer for measuring and/or protecting <strong>up to 0,72 kV</strong>, used for measurement instruments, meters, relays and other similar devices.  Designed to be used indoors/outdoors.</p>
<p style="font-weight: 400; text-align: justify;">The active part is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour. It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.</p>
<p style="font-weight: 400; text-align: justify;">Possibility of installation in any position.</p>
<p style="font-weight: 400; text-align: justify;">In this series of transformers, the dimensions depend both on the number of secondaries and on the burden and accuracy class of the secondary ones.</p>
<p style="font-weight: 400; text-align: justify;">Manufactured in accordance with <strong>IEC 61869:1</strong> and <strong>IEC 61869:2</strong> standards.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/AKBF-06_Catalogo_Castellano_2019.pdf">AKBF-06 Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_en_color-web.pdf">User Manual</a>
<a href="https://lescop.com/wp-content/uploads/2019/10/Catálogo-Accesorios-Transformadores.pdf">Accesories</a>
<a href="https://www.dropbox.com/sh/42n8v7i5jsofimq/AADhj8Xag6lV8BjB-Qi6BmW4a?dl=0">Planes (.dwg)</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2747</post-id>	</item>
		<item>
		<title>AKH-01/02.Insulation Voltage 0,72kV.Homopolar Toroidal Type.</title>
		<link>https://lescop.com/en/catalogo/instrument-transformers/indoor-current/akh-01-02-insulation-voltage-072-kv-homopolar-current-transformer-toroidal-type/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Fri, 09 Aug 2019 07:13:37 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/uncategorized/akh-01-02-insulation-voltage-072-kv-homopolar-current-transformer-toroidal-type/</guid>

					<description><![CDATA[<p style="font-weight: 400; text-align: justify;">LV transformer for measuring and/or protecting <strong>up to 0,72 kV</strong>, used for measurement instruments, meters, relays and other similar devices. Designed to be used indoors.</p>
<p style="font-weight: 400; text-align: justify;">The transformer <strong>AKH-01/02</strong> has been designed to detect homopolar currents. Its carries out the summation of the three currents in an only core, giving as a result a secondary current proportional to the primary homopolar current.</p>
<p style="font-weight: 400; text-align: justify;">The active part is occluded in class B polyurethane resin (according to IEC 60085 standard), in black colour. It provides high chemical resistance.</p>
<p style="font-weight: 400; text-align: justify;">Manufactured in accordance with <strong>IEC 61869:1</strong> and <strong>IEC 61869:2</strong> standards.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/AKH-01-02_Catalogo_Ingles_2019.pdf">AKH-01/02 Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_en_color-web.pdf">User Manual</a>
<a href="https://www.dropbox.com/sh/048b47t6a4ux21t/AACmN9Njii6s0wNeiiKqU5B_a?dl=0">Plane (.dwg)</a>]]></description>
										<content:encoded><![CDATA[<p style="font-weight: 400; text-align: justify;">LV transformer for measuring and/or protecting <strong>up to 0,72 kV</strong>, used for measurement instruments, meters, relays and other similar devices. Designed to be used indoors.</p>
<p style="font-weight: 400; text-align: justify;">The transformer <strong>AKH-01/02</strong> has been designed to detect homopolar currents. Its carries out the summation of the three currents in an only core, giving as a result a secondary current proportional to the primary homopolar current.</p>
<p style="font-weight: 400; text-align: justify;">The active part is occluded in class B polyurethane resin (according to IEC 60085 standard), in black colour. It provides high chemical resistance.</p>
<p style="font-weight: 400; text-align: justify;">Manufactured in accordance with <strong>IEC 61869:1</strong> and <strong>IEC 61869:2</strong> standards.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/AKH-01-02_Catalogo_Ingles_2019.pdf">AKH-01/02 Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_en_color-web.pdf">User Manual</a>
<a href="https://www.dropbox.com/sh/048b47t6a4ux21t/AACmN9Njii6s0wNeiiKqU5B_a?dl=0">Plane (.dwg)</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2759</post-id>	</item>
		<item>
		<title>AER-36.Insulation Voltage 36kV.Support Type.</title>
		<link>https://lescop.com/en/catalogo/instrument-transformers/indoor-current/aer-36-insulation-voltage-36-kv-support-type/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Thu, 08 Aug 2019 11:56:22 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/uncategorized/aer-36-insulation-voltage-36-kv-support-type/</guid>

					<description><![CDATA[<p style="font-weight: 400; text-align: justify;">HV Current transformer for measuring and/or protecting <strong>up to 36 kV</strong>, used for measurement instruments, meters, relays and other similar devices.  Designed to be used indoors.</p>
<p style="font-weight: 400; text-align: justify;">The primary winding is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour.</p>
<p style="font-weight: 400; text-align: justify;">It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.</p>
<p style="font-weight: 400; text-align: justify;">Possibility of installation in any position.</p>
<p style="font-weight: 400; text-align: justify;">Manufactured in accordance with <strong>IEC 61869:1</strong> and <strong>IEC 61869:2</strong> standards.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/AER-36_Catalogo_Ingles_2019.pdf">AER-36 Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_en_color-web.pdf">User Manual</a>
<a href="https://lescop.com/wp-content/uploads/2019/10/Catálogo-Accesorios-Transformadores.pdf">Accesories Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2023/05/9425070.001-ESQUEMAS-TI.pdf">TI Connection diagram</a>
<a href="https://www.dropbox.com/s/gpu1xdfr2l1e7v2/TI%20AER-36%20Laboratorio%20Electrot%C3%A9cnico.dwg?dl=0">Plane (.dwg)</a>]]></description>
										<content:encoded><![CDATA[<p style="font-weight: 400; text-align: justify;">HV Current transformer for measuring and/or protecting <strong>up to 36 kV</strong>, used for measurement instruments, meters, relays and other similar devices.  Designed to be used indoors.</p>
<p style="font-weight: 400; text-align: justify;">The primary winding is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour.</p>
<p style="font-weight: 400; text-align: justify;">It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.</p>
<p style="font-weight: 400; text-align: justify;">Possibility of installation in any position.</p>
<p style="font-weight: 400; text-align: justify;">Manufactured in accordance with <strong>IEC 61869:1</strong> and <strong>IEC 61869:2</strong> standards.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/AER-36_Catalogo_Ingles_2019.pdf">AER-36 Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_en_color-web.pdf">User Manual</a>
<a href="https://lescop.com/wp-content/uploads/2019/10/Catálogo-Accesorios-Transformadores.pdf">Accesories Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2023/05/9425070.001-ESQUEMAS-TI.pdf">TI Connection diagram</a>
<a href="https://www.dropbox.com/s/gpu1xdfr2l1e7v2/TI%20AER-36%20Laboratorio%20Electrot%C3%A9cnico.dwg?dl=0">Plane (.dwg)</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2734</post-id>	</item>
		<item>
		<title>AER-24.Insulation Voltage 24kV.Support Type.</title>
		<link>https://lescop.com/en/catalogo/instrument-transformers/indoor-current/aer-24-insulation-voltage-24-kv-support-type/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Thu, 08 Aug 2019 11:43:08 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/uncategorized/aer-24-insulation-voltage-24-kv-support-type/</guid>

					<description><![CDATA[<p style="font-weight: 400; text-align: justify;">HV Current transformer for measuring and/or protecting <strong>up to 24 kV</strong>, used for measurement instruments, meters, relays and other similar devices. Designed to be used indoors.</p>
<p style="font-weight: 400; text-align: justify;">The primary winding is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour.</p>
<p style="font-weight: 400; text-align: justify;">It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.</p>
<p style="font-weight: 400; text-align: justify;">Possibility of installation in any position.</p>
<p style="font-weight: 400; text-align: justify;">Manufactured in accordance with <strong>IEC 61869:1</strong> and <strong>IEC 61869:2</strong> standards.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/AER-24_Catalogo_Ingles_2019.pdf">AER-24 Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_en_color-web.pdf">User Manual</a>
<a href="https://lescop.com/wp-content/uploads/2019/10/Catálogo-Accesorios-Transformadores.pdf">Accesories Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2023/05/9425070.001-ESQUEMAS-TI.pdf">TI Connection diagram</a>
<a href="https://www.dropbox.com/s/03h5ymdoviqzgcx/TI%20AER-24%20Laboratorio%20Electrot%C3%A9cnico.dwg?dl=0">Plane (.dwg)</a>]]></description>
										<content:encoded><![CDATA[<p style="font-weight: 400; text-align: justify;">HV Current transformer for measuring and/or protecting <strong>up to 24 kV</strong>, used for measurement instruments, meters, relays and other similar devices. Designed to be used indoors.</p>
<p style="font-weight: 400; text-align: justify;">The primary winding is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour.</p>
<p style="font-weight: 400; text-align: justify;">It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.</p>
<p style="font-weight: 400; text-align: justify;">Possibility of installation in any position.</p>
<p style="font-weight: 400; text-align: justify;">Manufactured in accordance with <strong>IEC 61869:1</strong> and <strong>IEC 61869:2</strong> standards.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/AER-24_Catalogo_Ingles_2019.pdf">AER-24 Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_en_color-web.pdf">User Manual</a>
<a href="https://lescop.com/wp-content/uploads/2019/10/Catálogo-Accesorios-Transformadores.pdf">Accesories Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2023/05/9425070.001-ESQUEMAS-TI.pdf">TI Connection diagram</a>
<a href="https://www.dropbox.com/s/03h5ymdoviqzgcx/TI%20AER-24%20Laboratorio%20Electrot%C3%A9cnico.dwg?dl=0">Plane (.dwg)</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2722</post-id>	</item>
		<item>
		<title>AED-36.Insulation Voltage 36kV.Support Type.</title>
		<link>https://lescop.com/en/catalogo/instrument-transformers/indoor-current/aed-36-insulation-voltage-36-kv-support-type/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Thu, 08 Aug 2019 11:12:14 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/uncategorized/aed-36-insulation-voltage-36-kv-support-type/</guid>

					<description><![CDATA[<p style="font-weight: 400; text-align: justify;">HV Current transformer for measuring and/or protecting <strong>up to 36 kV</strong>, used for measurement instruments, meters, relays and other similar devices. Designed to be used indoors.</p>
<p style="font-weight: 400; text-align: justify;">The primary winding is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour.</p>
<p style="font-weight: 400; text-align: justify;">It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.</p>
<p style="font-weight: 400; text-align: justify;">Possibility of installation in any position.</p>
<p style="font-weight: 400; text-align: justify;">Manufactured in accordance with <strong>IEC 61869:1</strong> and <strong>IEC 61869:2</strong> standards.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/AED-36_Catalogo_Ingles_2019.pdf">AED-36 Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_en_color-web.pdf">User Manual</a>
<a href="https://lescop.com/wp-content/uploads/2019/10/Catálogo-Accesorios-Transformadores.pdf">Accesories Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2023/05/9425070.001-ESQUEMAS-TI.pdf">TI Connection diagram</a>
<a href="https://www.dropbox.com/s/semm0opahdq9zp5/TI%20AED-36%20Laboratorio%20Electrot%C3%A9cnico.dwg?dl=0">Plane (.dwg)</a>]]></description>
										<content:encoded><![CDATA[<p style="font-weight: 400; text-align: justify;">HV Current transformer for measuring and/or protecting <strong>up to 36 kV</strong>, used for measurement instruments, meters, relays and other similar devices. Designed to be used indoors.</p>
<p style="font-weight: 400; text-align: justify;">The primary winding is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour.</p>
<p style="font-weight: 400; text-align: justify;">It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.</p>
<p style="font-weight: 400; text-align: justify;">Possibility of installation in any position.</p>
<p style="font-weight: 400; text-align: justify;">Manufactured in accordance with <strong>IEC 61869:1</strong> and <strong>IEC 61869:2</strong> standards.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/AED-36_Catalogo_Ingles_2019.pdf">AED-36 Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_en_color-web.pdf">User Manual</a>
<a href="https://lescop.com/wp-content/uploads/2019/10/Catálogo-Accesorios-Transformadores.pdf">Accesories Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2023/05/9425070.001-ESQUEMAS-TI.pdf">TI Connection diagram</a>
<a href="https://www.dropbox.com/s/semm0opahdq9zp5/TI%20AED-36%20Laboratorio%20Electrot%C3%A9cnico.dwg?dl=0">Plane (.dwg)</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2696</post-id>	</item>
		<item>
		<title>AED-24.Insulation Voltage 24kV.Support Type.</title>
		<link>https://lescop.com/en/catalogo/instrument-transformers/indoor-current/aed-24-insulation-voltage-24-kv-support-type/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Thu, 08 Aug 2019 11:01:55 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/uncategorized/aed-12-insulation-voltage-12-kv-support-type/</guid>

					<description><![CDATA[<p style="font-weight: 400; text-align: justify;">HV Current transformer for measuring and/or protecting <strong>up to 24 kV</strong>, used for measurement instruments, meters, relays and other similar devices.  Designed to be used indoors.</p>
<p style="font-weight: 400; text-align: justify;">The primary winding is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour.</p>
<p style="font-weight: 400; text-align: justify;">It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.</p>
<p style="font-weight: 400; text-align: justify;">Possibility of installation in any position.</p>
<p style="font-weight: 400; text-align: justify;">Manufactured in accordance with <strong>IEC 61869:1</strong> and <strong>IEC 61869:2</strong> standards.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/AED-24_Catalogo_Ingles_2019.pdf">AED-24 Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_en_color-web.pdf">User Manual</a>
<a href="https://lescop.com/wp-content/uploads/2019/10/Catálogo-Accesorios-Transformadores.pdf">Accesories Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2023/05/9425070.001-ESQUEMAS-TI.pdf">TI Connection diagram</a>
<a href="https://www.dropbox.com/s/l6o5vcwocx5dfyb/TI%20AED-24%20Laboratorio%20Electrot%C3%A9cnico.dwg?dl=0">Plane (.dwg)</a>]]></description>
										<content:encoded><![CDATA[<p style="font-weight: 400; text-align: justify;">HV Current transformer for measuring and/or protecting <strong>up to 24 kV</strong>, used for measurement instruments, meters, relays and other similar devices.  Designed to be used indoors.</p>
<p style="font-weight: 400; text-align: justify;">The primary winding is occluded in class E epoxy resin (in accordance with IEC 60085 standard), brown colour.</p>
<p style="font-weight: 400; text-align: justify;">It is mechanically resistant and damp-proof, oil-proof, dust-proof and resists most chemical products.</p>
<p style="font-weight: 400; text-align: justify;">Possibility of installation in any position.</p>
<p style="font-weight: 400; text-align: justify;">Manufactured in accordance with <strong>IEC 61869:1</strong> and <strong>IEC 61869:2</strong> standards.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2019/10/AED-24_Catalogo_Ingles_2019.pdf">AED-24 Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/02/Manual-instrucciones-04-12-2019_en_color-web.pdf">User Manual</a>
<a href="https://lescop.com/wp-content/uploads/2019/10/Catálogo-Accesorios-Transformadores.pdf">Accesories Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2023/05/9425070.001-ESQUEMAS-TI.pdf">TI Connection diagram</a>
<a href="https://www.dropbox.com/s/l6o5vcwocx5dfyb/TI%20AED-24%20Laboratorio%20Electrot%C3%A9cnico.dwg?dl=0">Plane (.dwg)</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2661</post-id>	</item>
	</channel>
</rss>
