<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Lockers &#8211; Laboratorio Electrotécnico</title>
	<atom:link href="https://lescop.com/en/productos/lockers/feed/" rel="self" type="application/rss+xml" />
	<link>https://lescop.com/en/</link>
	<description>Transformadores a medida, aparellaje eléctrico</description>
	<lastBuildDate>Mon, 01 Dec 2025 13:29:33 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>
	<item>
		<title>ARM. Resistances Cabinet.</title>
		<link>https://lescop.com/en/catalogo/instrument-transformers/indoor-current/arm-resistances-cabinet-copia-copia-copia/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Mon, 13 Jun 2022 12:30:50 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.com/?post_type=product&#038;p=9099</guid>

					<description><![CDATA[<p style="text-align: justify;"><span lang="EN-GB">The load resistors cabinet <strong>ARM</strong> consists of a resistance box, a non-sealable terminal strip and a 2A circuit breaker, located in a metal cabinet with ventilation and connections protected by a sealable cover to prevent tampering.</span></p>
<p style="text-align: justify;"><span lang="EN-GB">Box load resistors, is comprised of three load resistors contained in a metal box with surface treatment to prevent corrosion and to evacuate the heat.</span></p>
<p style="text-align: justify;"><span lang="EN-GB">It is designed for indoor use. </span>On request it can be manufactured for outdoor service and with different configurations.</p>
<p style="text-align: justify;">Its function is to <strong>consume the necessary power for the transformer to work at least at 25% of the accuracy burden</strong> in cases where the loads connected to the unit (meters, relays,etc.) do not reach the minimum necessary to guaranteed measurement accuracy.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2021/05/CI.ARM_.-Inglés-ARM.pdf" target="_blank" rel="noopener noreferrer">ARM Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/03/User-Manual-ARM150-07-02-2020-Web.pdf">User Manual ARM</a>]]></description>
										<content:encoded><![CDATA[<p style="text-align: justify;"><span lang="EN-GB">The load resistors cabinet <strong>ARM</strong> consists of a resistance box, a non-sealable terminal strip and a 2A circuit breaker, located in a metal cabinet with ventilation and connections protected by a sealable cover to prevent tampering.</span></p>
<p style="text-align: justify;"><span lang="EN-GB">Box load resistors, is comprised of three load resistors contained in a metal box with surface treatment to prevent corrosion and to evacuate the heat.</span></p>
<p style="text-align: justify;"><span lang="EN-GB">It is designed for indoor use. </span>On request it can be manufactured for outdoor service and with different configurations.</p>
<p style="text-align: justify;">Its function is to <strong>consume the necessary power for the transformer to work at least at 25% of the accuracy burden</strong> in cases where the loads connected to the unit (meters, relays,etc.) do not reach the minimum necessary to guaranteed measurement accuracy.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2021/05/CI.ARM_.-Inglés-ARM.pdf" target="_blank" rel="noopener noreferrer">ARM Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/03/User-Manual-ARM150-07-02-2020-Web.pdf">User Manual ARM</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">9099</post-id>	</item>
		<item>
		<title>ARM TT+TI. Load resistor cabinet for a set of VT &#038; CT.</title>
		<link>https://lescop.com/en/catalogo/instrument-transformers/indoor-current/arm-resistances-cabinet-copia-copia/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Mon, 13 Jun 2022 12:14:39 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.com/?post_type=product&#038;p=9091</guid>

					<description><![CDATA[<p data-path-to-node="4">The <b>ARM TT+TI</b> is a load resistor cabinet designed for a set of voltage and current transformers (VT &#38; CT). It comprises a slotted enclosure containing 3 resistors (current circuit), a group of 3 resistors (voltage circuit), their respective <b>terminal block</b>, and a <b>2 A Miniature Circuit Breaker (MCB)</b>. These components are housed in a metal cabinet featuring ventilation (natural or forced, depending on the requested specifications), with connections protected by a <b>sealable cover</b>.</p>
<p data-path-to-node="5">The cabinet is manufactured from sheet steel (lacquered or stainless, according to requirements) and features a <b>3 mm double-bit lock</b> operated by a cam, sealed via a slotted screw to prevent unauthorized tampering.</p>
<p data-path-to-node="6">It is designed for <b>indoor service</b>. Upon request, it can be manufactured for outdoor service, as well as in various other configurations.</p>
<p data-path-to-node="7">Its function is to consume the necessary power to ensure the transformers operate at a minimum of <b>25% of their rated accuracy burden</b>. This applies in cases where the loads connected to the device (meters, relays, etc.) do not reach the minimum threshold required to guarantee measurement accuracy.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2021/05/CI.ARM_.-Inglés-ARM.pdf" target="_blank" rel="noopener noreferrer">ARM Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/03/User-Manual-ARM150-07-02-2020-Web.pdf">User Manual ARM</a>]]></description>
										<content:encoded><![CDATA[<p data-path-to-node="4">The <b>ARM TT+TI</b> is a load resistor cabinet designed for a set of voltage and current transformers (VT &#38; CT). It comprises a slotted enclosure containing 3 resistors (current circuit), a group of 3 resistors (voltage circuit), their respective <b>terminal block</b>, and a <b>2 A Miniature Circuit Breaker (MCB)</b>. These components are housed in a metal cabinet featuring ventilation (natural or forced, depending on the requested specifications), with connections protected by a <b>sealable cover</b>.</p>
<p data-path-to-node="5">The cabinet is manufactured from sheet steel (lacquered or stainless, according to requirements) and features a <b>3 mm double-bit lock</b> operated by a cam, sealed via a slotted screw to prevent unauthorized tampering.</p>
<p data-path-to-node="6">It is designed for <b>indoor service</b>. Upon request, it can be manufactured for outdoor service, as well as in various other configurations.</p>
<p data-path-to-node="7">Its function is to consume the necessary power to ensure the transformers operate at a minimum of <b>25% of their rated accuracy burden</b>. This applies in cases where the loads connected to the device (meters, relays, etc.) do not reach the minimum threshold required to guarantee measurement accuracy.</p>
&#160;

<a href="https://lescop.com/wp-content/uploads/2021/05/CI.ARM_.-Inglés-ARM.pdf" target="_blank" rel="noopener noreferrer">ARM Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/03/User-Manual-ARM150-07-02-2020-Web.pdf">User Manual ARM</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">9091</post-id>	</item>
		<item>
		<title>ARM TI. Load resistor cabinet for CT.</title>
		<link>https://lescop.com/en/catalogo/instrument-transformers/indoor-current/arm-resistances-cabinet-copia/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Mon, 13 Jun 2022 11:45:02 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.com/?post_type=product&#038;p=9083</guid>

					<description><![CDATA[<p data-path-to-node="4">The <b>ARM TI</b> is a load resistor cabinet designed for <b>Current Transformers (CT)</b>. It comprises a slotted enclosure containing 3 resistors and their respective terminal block, housed in a metal cabinet featuring ventilation (natural or forced, depending on the requested specifications), with connections protected by a <b>sealable cover</b>.</p>
<p data-path-to-node="5">The cabinet is manufactured from sheet steel (lacquered or stainless, according to requirements) and features a <b>3 mm double-bit lock</b> operated by a cam, sealed via a slotted screw to prevent unauthorized <b>tampering</b>.</p>
<p data-path-to-node="6">It is designed for <b>indoor service</b>. Upon request, it can be manufactured for outdoor service, as well as in various other configurations.</p>
<p data-path-to-node="7">Its function is to consume the necessary power to ensure the transformer operates <b>between 25% and 100% of its rated accuracy burden</b>. This applies in cases where the loads connected to the device (meters, relays, etc.) do not reach the minimum threshold required to guarantee measurement accuracy.</p>
<a href="https://lescop.com/wp-content/uploads/2021/05/CI.ARM_.-Inglés-ARM.pdf" target="_blank" rel="noopener noreferrer">ARM Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/03/User-Manual-ARM150-07-02-2020-Web.pdf">User Manual ARM</a>]]></description>
										<content:encoded><![CDATA[<p data-path-to-node="4">The <b>ARM TI</b> is a load resistor cabinet designed for <b>Current Transformers (CT)</b>. It comprises a slotted enclosure containing 3 resistors and their respective terminal block, housed in a metal cabinet featuring ventilation (natural or forced, depending on the requested specifications), with connections protected by a <b>sealable cover</b>.</p>
<p data-path-to-node="5">The cabinet is manufactured from sheet steel (lacquered or stainless, according to requirements) and features a <b>3 mm double-bit lock</b> operated by a cam, sealed via a slotted screw to prevent unauthorized <b>tampering</b>.</p>
<p data-path-to-node="6">It is designed for <b>indoor service</b>. Upon request, it can be manufactured for outdoor service, as well as in various other configurations.</p>
<p data-path-to-node="7">Its function is to consume the necessary power to ensure the transformer operates <b>between 25% and 100% of its rated accuracy burden</b>. This applies in cases where the loads connected to the device (meters, relays, etc.) do not reach the minimum threshold required to guarantee measurement accuracy.</p>
<a href="https://lescop.com/wp-content/uploads/2021/05/CI.ARM_.-Inglés-ARM.pdf" target="_blank" rel="noopener noreferrer">ARM Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/03/User-Manual-ARM150-07-02-2020-Web.pdf">User Manual ARM</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">9083</post-id>	</item>
		<item>
		<title>Fuse Holder Cabinet</title>
		<link>https://lescop.com/en/catalogo/lockers/holders-closet/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Wed, 07 Aug 2019 11:20:05 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/uncategorized/holders-closet/</guid>

					<description><![CDATA[<div class="content-wrapper clearfix">
<div class="container single-portfolio">
<div class="eleven columns">
<div class="portfolio-single-description clearfix">

<span class="tlid-translation translation" lang="en"><span class="" title="">Cabinet for short-circuit protection of three-phase lines<strong> up to 12 kV.</strong></span></span>

</div>
</div>
<div class="clear"></div>
<div class="sixteen columns"></div>
</div>
</div>
<div class="footer-wrapper"></div>]]></description>
										<content:encoded><![CDATA[<div class="content-wrapper clearfix">
<div class="container single-portfolio">
<div class="eleven columns">
<div class="portfolio-single-description clearfix">

<span class="tlid-translation translation" lang="en"><span class="" title="">Cabinet for short-circuit protection of three-phase lines<strong> up to 12 kV.</strong></span></span>

</div>
</div>
<div class="clear"></div>
<div class="sixteen columns"></div>
</div>
</div>
<div class="footer-wrapper"></div>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2442</post-id>	</item>
		<item>
		<title>ARM TT. Load resistor cabinet for VT.</title>
		<link>https://lescop.com/en/catalogo/instrument-transformers/indoor-voltage-transformers/resistances-cabinet-arm/</link>
		
		<dc:creator><![CDATA[Laboratorio Electrotécnico]]></dc:creator>
		<pubDate>Fri, 02 Aug 2019 15:02:32 +0000</pubDate>
				<guid isPermaLink="false">https://lescop.panelserver.org/catalogo/uncategorized/resistances-cabinet-arm/</guid>

					<description><![CDATA[<p data-path-to-node="4">The <b>ARM TT</b> is a load resistor cabinet designed for <b>Voltage Transformers (VT)</b>. It consists of <b>one to three groups of 3 resistors</b>, their respective terminal block, and a <b>2 A Miniature Circuit Breaker (MCB)</b>. These components are housed in a metal cabinet featuring ventilation (natural or forced, depending on the requested specifications), with connections protected by a <b>sealable cover</b>.</p>
<p data-path-to-node="5">The cabinet is manufactured from sheet steel (lacquered or stainless, according to requirements) and features a <b>3 mm double-bit lock</b> operated by a cam, sealed via a slotted screw to prevent unauthorized <b>tampering</b>.</p>
<p data-path-to-node="6">It is designed for <b>indoor service</b>. Upon request, it can be manufactured for outdoor service, as well as in various other configurations.</p>
<p data-path-to-node="7">Its function is to consume the necessary power to ensure the transformer operates at a minimum of <b>25% of its rated accuracy burden</b>. This applies in cases where the loads connected to the device (meters, relays, etc.) do not reach the minimum threshold required to guarantee measurement accuracy.

</p>
<a href="https://lescop.com/wp-content/uploads/2021/05/CI.ARM_.-Inglés-ARM.pdf" target="_blank" rel="noopener noreferrer">ARM Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/03/User-Manual-ARM150-07-02-2020-Web.pdf">User Manual ARM</a>]]></description>
										<content:encoded><![CDATA[<p data-path-to-node="4">The <b>ARM TT</b> is a load resistor cabinet designed for <b>Voltage Transformers (VT)</b>. It consists of <b>one to three groups of 3 resistors</b>, their respective terminal block, and a <b>2 A Miniature Circuit Breaker (MCB)</b>. These components are housed in a metal cabinet featuring ventilation (natural or forced, depending on the requested specifications), with connections protected by a <b>sealable cover</b>.</p>
<p data-path-to-node="5">The cabinet is manufactured from sheet steel (lacquered or stainless, according to requirements) and features a <b>3 mm double-bit lock</b> operated by a cam, sealed via a slotted screw to prevent unauthorized <b>tampering</b>.</p>
<p data-path-to-node="6">It is designed for <b>indoor service</b>. Upon request, it can be manufactured for outdoor service, as well as in various other configurations.</p>
<p data-path-to-node="7">Its function is to consume the necessary power to ensure the transformer operates at a minimum of <b>25% of its rated accuracy burden</b>. This applies in cases where the loads connected to the device (meters, relays, etc.) do not reach the minimum threshold required to guarantee measurement accuracy.

</p>
<a href="https://lescop.com/wp-content/uploads/2021/05/CI.ARM_.-Inglés-ARM.pdf" target="_blank" rel="noopener noreferrer">ARM Catalog</a>
<a href="https://lescop.com/wp-content/uploads/2020/03/User-Manual-ARM150-07-02-2020-Web.pdf">User Manual ARM</a>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2436</post-id>	</item>